Description
The JA-110M bus module is used to connect wired magnetic door/window detectors to the bus and contains two independent inputs programmable to be NC/NO or using a balancing resistor.
JA-110M Bus module for magnetic detectors – 2 inputs
Allows you to set a minimum time for alarm activation (0.5 s, 1 s, 2 s or 5 s).
The detector communicates with and is powered by the control panel bus. The detector is addressable and occupies two positions in the system.
SMART MEMORY indication (SMI) provides a visual (LED) verification of detector triggering. SMI is reset via the keypad.
Technical specifications
| Power | 12 V bus (9 … 15 V) |
|---|---|
| Current consumption in standby (quiescent) | 5 mA |
| Current consumption for choice of cable | 5 mA |
| Maximum length of cable to the detector input | 3 m |
| Dimensions | 100 x 40 x 24 mm |
| Classification | grade 2 according to EN 50131-1, EN 50131-3 |
| Environment | EN 50131-1. general indoor |
| Operating temperature range | -10 to +40 ° C |
| Complies with /th> | EN 50130-4, EN 55022 |






Reviews
There are no reviews yet.